Dr1 Rat shRNA Plasmid (Locus ID 289881)
CAT#: TL701428
Dr1 - Rat, 4 unique 29mer shRNA constructs in lentiviral GFP vector, 5µg of each construct provided
Need custom shRNA service?
Get a free quote
CNY 7,740.00
货期*
2周
规格
Product images
经常一起买 (3)
Specifications
Product Data | |
Product Name | Dr1 Rat shRNA Plasmid (Locus ID 289881) |
Locus ID | 289881 |
UniProt ID | Q5XI68 |
Vector | pGFP-C-shLenti |
Format | Lentiviral plasmids |
Kit Components | Dr1 - Rat, 4 unique 29mer shRNA constructs in lentiviral GFP vector(Gene ID = 289881). 5µg purified plasmid DNA per construct29-mer scrambled shRNA cassette in pGFP-C-shLenti Vector, TR30021, included for free. |
RefSeq | NM_001011914, NM_001011914.1, BC083822 |
Summary | The association of the DR1/DRAP1 heterodimer with TBP results in a functional repression of both activated and basal transcription of class II genes. This interaction precludes the formation of a transcription-competent complex by inhibiting the association of TFIIA and/or TFIIB with TBP. Can bind to DNA on its own. Component of the ATAC complex, a complex with histone acetyltransferase activity on histones H3 and H4 (By similarity).[UniProtKB/Swiss-Prot Function] |
shRNA Design | These shRNA constructs were designed against multiple splice variants at this gene locus. To be certain that your variant of interest is targeted, please contact techsupport@origene.com. If you need a special design or shRNA sequence, please utilize our custom shRNA service. |
Performance Guaranteed | OriGene guarantees that the sequences in the shRNA expression cassettes are verified to correspond to the target gene with 100% identity. One of the four constructs at minimum are guaranteed to produce 70% or more gene expression knock-down provided a minimum transfection efficiency of 80% is achieved. Western Blot data is recommended over qPCR to evaluate the silencing effect of the shRNA constructs 72 hrs post transfection. To properly assess knockdown, the gene expression level from the included scramble control vector must be used in comparison with the target-specific shRNA transfected samples. For non-conforming shRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the shRNA kit. To arrange for a free replacement with newly designed constructs, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled shRNA control (Western Blot data preferred). |