KIAA1530 (UVSSA) Human shRNA Plasmid Kit (Locus ID 57654)

CAT#: TL307192

UVSSA - Human, 4 unique 29mer shRNA constructs in lentiviral GFP vector, 5µg of each construct provided



Need custom shRNA service?
Get a free quote

CNY 7,125.00


货期*
3周

规格
    • 1 kit

Product images

经常一起买 (4)
Lenti-vpak packaging kit - packaging plasmids and transfection reagent
    • 10 reactions

CNY 5,420.00


TurboFectin Transfection Reagent (1 mL in 1 vial)
    • 1 ml in 1 vial

CNY 4,090.00


UVSSA Antibody - C-terminal region
    • 100 ul

CNY 5,250.00


Lateral flow testing sticks used for the semi-quantitative detection of the lentiviral p24 protein, 20 tests
    • 20 Tests

CNY 4,070.00

Specifications

Product Data
Product Name KIAA1530 (UVSSA) Human shRNA Plasmid Kit (Locus ID 57654)
Locus ID 57654
UniProt ID Q2YD98
Synonyms KIAA1530; UVSS3
Vector pGFP-C-shLenti
Format Lentiviral plasmids
Kit Components UVSSA - Human, 4 unique 29mer shRNA constructs in lentiviral GFP vector(Gene ID = 57654). 5µg purified plasmid DNA per construct
29-mer scrambled shRNA cassette in pGFP-C-shLenti Vector, TR30021, included for free.
RefSeq BC021930, NM_001317934, NM_001317935, NM_020894, NM_020894.1, NM_020894.2, NM_020894.3, BC021930.1, BC110331, BC110331.1, BC140901, NM_020894.4
Summary The protein encoded by this gene appears to be involved in ubiquitination and dephosphorylation of RNA polymerase II subunits that stall after UV irradiation. The encoded protein interacts with several members of the nucleotide excision repair complex, and is thought to be involved in the transcription-coupled nucleotide excision repair (TC-NER) pathway to help remove lesions in the DNA that block transcription. Defects in this gene can cause UV-sensitive syndrome 3. Alternative splicing results in multiple transcript variants. [provided by RefSeq, Dec 2015]
shRNA Design These shRNA constructs were designed against multiple splice variants at this gene locus. To be certain that your variant of interest is targeted, please contact techsupport@origene.com. If you need a special design or shRNA sequence, please utilize our custom shRNA service.
Performance Guaranteed OriGene guarantees that the sequences in the shRNA expression cassettes are verified to correspond to the target gene with 100% identity. One of the four constructs at minimum are guaranteed to produce 70% or more gene expression knock-down provided a minimum transfection efficiency of 80% is achieved. Western Blot data is recommended over qPCR to evaluate the silencing effect of the shRNA constructs 72 hrs post transfection. To properly assess knockdown, the gene expression level from the included scramble control vector must be used in comparison with the target-specific shRNA transfected samples.

For non-conforming shRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the shRNA kit. To arrange for a free replacement with newly designed constructs, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled shRNA control (Western Blot data preferred).
*Delivery time may vary from web posted schedule. Occasional delays may occur due to unforeseen complexities in the preparation of your product. International customers may expect an additional 1-2 weeks in shipping.
Customer Reviews 
Loading...