NUDT6 Human siRNA Oligo Duplex (Locus ID 11162)

CAT#: SR307651

NUDT6 (Human) - 3 unique 27mer siRNA duplexes - 2 nmol each



Need single siRNA in bulk?
Get a free quote

CNY 1,500.00

CNY 4,090.00


货期*
7周

规格
    • 1 kit

Product images

经常一起买 (3)
siTran 2.0 siRNA transfection reagent (0.5ml)
    • 500 ul

CNY 2,190.00


Trilencer-27 Fluorescent-labeled transfection control siRNA duplex - 1 nmol
    • 1 nmol

CNY 1,090.00


NUDT6 mouse monoclonal antibody, clone OTI9D12 (formerly 9D12)
    • 100 ul

CNY 1,999.00
CNY 2,700.00

Specifications

Product Data
Purity HPLC purified
Quality Control Tested by ESI-MS
Sequences Available with shipment
Stability One year from date of shipment when stored at -20°C.
# of transfections Approximately 330 transfections/2nmol in 24-well plate under optimized conditions (final conc. 10 nM).
Note Single siRNA duplex (10nmol) can be ordered.
Reference Data
RefSeq NM_007083, NM_198041
Synonyms ASFGF2; FGF-AS; FGF2AS; GFG-1; GFG1
Components NUDT6 (Human) - 3 unique 27mer siRNA duplexes - 2 nmol each (Locus ID 11162)
Included - SR30004, Trilencer-27 Universal Scrambled Negative Control siRNA Duplex - 2 nmol
Included - SR30005, RNAse free siRNA Duplex Resuspension Buffer - 2 ml
Summary This gene overlaps and lies on the opposite strand from FGF2 gene, and is thought to be the FGF2 antisense gene. The two genes are independently transcribed, and their expression shows an inverse relationship, suggesting that this antisense transcript may regulate FGF2 expression. This gene has also been shown to have hormone-regulatory and antiproliferative actions in the pituitary that are independent of FGF2 expression. Alternatively spliced transcript variants encoding different isoforms have been found for this gene. [provided by RefSeq, Oct 2011]
Performance Guranteed OriGene guarantees that at least two of the three Dicer-Substrate duplexes in the kit will provide at least 70% or more knockdown of the target mRNA when used at 10 nM concentration by quantitative RT-PCR when the TYE-563 fluorescent transfection control duplex (cat# SR30002) indicates that >90% of the cells have been transfected and the HPRT positive control (cat# SR30003) provides 90% knockdown efficiency.

For non-conforming siRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the siRNA kit. To arrange for a free replacement with newly designed duplexes, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled siRNA control (quantitative RT-PCR data required).
*Delivery time may vary from web posted schedule. Occasional delays may occur due to unforeseen complexities in the preparation of your product. International customers may expect an additional 1-2 weeks in shipping.

Documents

Customer Reviews 
Loading...