BAP1 Human shRNA Plasmid Kit (Locus ID 8314)
CAT#: TF314513
BAP1 - Human, 4 unique 29mer shRNA constructs in retroviral RFP vector, 5µg of each construct provided
Need custom shRNA service?
Get a free quote
CNY 4,790.00
货期*
现货
规格
Product images
经常一起买 (2)
Specifications
Product Data | |
Product Name | BAP1 Human shRNA Plasmid Kit (Locus ID 8314) |
Locus ID | 8314 |
UniProt ID | Q92560 |
Synonyms | hucep-6; HUCEP-13; UCHL2 |
Vector | pRFP-C-RS |
Format | Retroviral plasmids |
Kit Components | BAP1 - Human, 4 unique 29mer shRNA constructs in retroviral RFP vector(Gene ID = 8314). 5µg purified plasmid DNA per construct29-mer scrambled shRNA cassette in pRFP-C-RS Vector, TR30015, included for free. |
RefSeq | NM_004656, NM_004656.1, NM_004656.2, NM_004656.3, BC001596, NM_004656.4 |
Summary | This gene belongs to the ubiquitin C-terminal hydrolase subfamily of deubiquitinating enzymes that are involved in the removal of ubiquitin from proteins. The encoded enzyme binds to the breast cancer type 1 susceptibility protein (BRCA1) via the RING finger domain of the latter and acts as a tumor suppressor. In addition, the enzyme may be involved in regulation of transcription, regulation of cell cycle and growth, response to DNA damage and chromatin dynamics. Germline mutations in this gene may be associated with tumor predisposition syndrome (TPDS), which involves increased risk of cancers including malignant mesothelioma, uveal melanoma and cutaneous melanoma. [provided by RefSeq, May 2013] |
shRNA Design | These shRNA constructs were designed against multiple splice variants at this gene locus. To be certain that your variant of interest is targeted, please contact techsupport@origene.com. If you need a special design or shRNA sequence, please utilize our custom shRNA service. |
Performance Guaranteed | OriGene guarantees that the sequences in the shRNA expression cassettes are verified to correspond to the target gene with 100% identity. One of the four constructs at minimum are guaranteed to produce 70% or more gene expression knock-down provided a minimum transfection efficiency of 80% is achieved. Western Blot data is recommended over qPCR to evaluate the silencing effect of the shRNA constructs 72 hrs post transfection. To properly assess knockdown, the gene expression level from the included scramble control vector must be used in comparison with the target-specific shRNA transfected samples. For non-conforming shRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the shRNA kit. To arrange for a free replacement with newly designed constructs, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled shRNA control (Western Blot data preferred). |
Documents
Product Manuals |
FAQs |
SDS |
Customer
Reviews
Loading...